MiCOM Agile P64x

Transformer Protection System

GE's MiCOM Agile platform of transformer protection relays helps preserve transformer service life and provides fast protection for transformer faults. The platform consists of three model variants (P642, P643 and P645) that cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs, and offers high and low impedance restricted earth fault, and has integral asset management capability.

Key Benefits

  • Secure high-speed protection for transformers, compliant with IEEE C37.91

  • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and IEC 61850-9-2 process bus solution ensures interoperability, device managing optimization and reduced cost of ownership

  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications

  • Improved security for transformer energization and inrush provided through a superior adaptive 2nd harmonic restraint algorithm

  • Three independent fiber or copper Ethernet ports for simultaneous/dedicated network connections with advanced 1 microsecond time synchronization via LAN with IEEE 1588 support

  • Sensitive ground fault protection provides low- impedance differential protection down to 5% of the winding to limit transformer damage

  • Phasor Measurement Unit (synchrophasor) according to IEEE C37.118 (2011) and IEC 61850-90-5 support

  • CyberSentry™ provides high-end cyber security aligned to industry standards and services (NERC CIP, AAA, Radius, RBAC, Syslog)

  • Reduced relay-to-relay wiring and associated installation costs through high-speed inter-relay communications

  • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization

  • An integrated large, full colour display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciate functionality and graphical visualization of phasors

Applications

  • Transformer asset monitoring using loss-of-life, aging factor, hottest spot

  • Applicable for transformers with up to six windings in a ring bus or breaker-and-a-half configuration

  • Reliable and secure protection for three-phase transformers, autotransformers, reactors, split-phase and phase angle regulating transformers

  • Stand-alone or component in automated substation control system

Key Features

Protection and Control

  • Dual-slope, dual-breakpoint differential restraint characteristic, restrained and unrestrained differential

  • 2nd harmonic inrush and overexcitation inhibit

  • Transformer overexcitation protection

  • Restricted ground fault

  • Loss-of-life, aging factor, hottest spot

  • Five zones backup distance protection with power swing detection and load encroachment function

  • Synchrocheck, ROCOF, over and under frequency

The T60 transformer protection system is a comprehensive three-phase transformer relay designed to protect medium and large power transformers. The T60 provides automatic or user-definable magnitude reference winding selections for CT ratio matching, and performs automatic phase shift compensation for all types of transformer winding connections. The T60 algorithm allows the user to enable removal of the zero-sequence current even for delta-connected transformer windings, facilitating transformers with a variety of grounding configurations. As part of the Universal Relay (UR) Family, the T60 provides superior protection and control.

Monitoring & Metering

  • Metering - current, voltage, power, energy, frequency, temperature, transformer monitoring

  • P & M class synchrophasors of voltage, current and sequence components – 1 to 120 frames/sec

  • Oscillography – analog and digital parameters at 64 samples/cycle

  • Event Recorder - 1024 time tagged events with 0.5ms scan of digital inputs

  • Data Logger - 16 channels with sampling rate up to 1 sample / cycle

  • Setting for security audit trails for tracking changes to T60 configurations

The T60 includes high accuracy metering and recording for all AC signals. Voltage, current, and power metering are built into the relay as a standard feature. Current and voltage parameters are available as total RMS magnitude, and as fundamental frequency magnitude and angle. For power quality applcations, harmonic measurements (up to the 25th) for voltage and current are available. T60 can monitor, calculate and log hottest-spot temperature, aging factor and loss-of-life data over a long period. This data, combined with economic analysis, allows criteria to be developed regarding the best time at which to replace a power transformer due to load growth, i.e. to minimize the cost without significantly increasing the risk.

The T60 incorporates advanced automation features including powerful FlexLogic™ programmable logic, communication, and SCADA capabilities that far surpass what is found in the average transformer relay. The T60 integrates seamlessly with other UR relays for complete system protection.

Communication

  • Complete IEC 61850 Process Bus solution providing resource optimization and minimizing total P & C life cycle costs

  • Three independent 100Mbps Ethernet ports enable purpose specific LAN support that eliminates latency effect of heavy traffic protocols on mission critical communication services

  • Embedded IEEE 1588 time synch protocol support eliminates dedicated IRIG-B wiring requirements for IEDs

  • Direct I/O secures high-speed exchange of binary data between URs

  • Increase network availability by reducing failover time to zero through IEC62439-3 “PRP” support

The T60 provides advanced communications technologies for remote data and engineering access, making it the most advanced and flexible transformer protection relay to use and integrate into new and existing infrastructures. Direct support for fiber optic Ethernet provides high-bandwidth communications allowing for low-latency controls and high-speed file transfers of relay fault and event record information. The available three independent and redundant Ethernet options provide the means to create fault tolerant communication architectures in an easy, cost-effective manner. 
The T60 supports the most popular industry standard protocols enabling easy, direct integration into DCS and SCADA systems.

  • IEC 61850 Ed. 1/Ed. 2 with 61850-9-2 (Process Bus) and 61850-90-5 (synchrophasors) support

  • DNP 3.0 (serial & TCP/IP)

  • Ethernet Global Data (EGD)

  • IEC 60870-5-103 and IEC 60870-5-104

  • Modbus RTU, Modbus TCP/IP

  • HTTP, TFTP, SFTP and MMS file transfer

  • Redundant SNTP and IEEE 1588 for time synchronization

  • PRP as per IEC 62439-3

  • Supports Routable GOOSE (R-GOOSE)

UR Switch Module

In addition to providing high-speed connectivity directly to your Universal Relay, the UR Switch Module provides an additional 4 fiber Ethernet ports, for connection to other relays in the system as well as upstream connectivity. It also provides 2 RJ45 copper Ethernet ports which can be used to connect local devices such as PCs, meters, or virtually anything else in the system.

The UR Switch Module provides a simple way to add fully-managed Ethernet networking to your relays and devices without the need for additional hardware or a dedicated communications cabinet.

The UR Switch Module includes all of the management and features that come with all MultiLink managed switches, and can be easily integrated into a network that has other Ethernet switches.

When used in a ring topology with other UR Switch Modules or MultiLink Switches, the UR Switch Module can be configured to use MultiLink’s Smart RSTP feature to provide industry-leading network recovery for ring topologies, at a speed of less than 5ms per switch. 

Interoperability with Enbedded IEC 61850

Use the T60 with integrated IEC 61850 to lower costs associated with generator protection, control and automation. GE’s leadership in IEC 61850 comes from thousands of installed devices and follows on years of development experience with UCA 2.0.

The T60’s IEC 61850 Process Bus module is designed to interface with the Multilin HardFiber System, allowing bi-directional IEC 61850 fiber optic communications. The HardFiber System is designed to integrate seamlessly with existing Universal Relay applications, including protection functions, FlexLogic, metering and communications.

Sofeware & Security

Cyber Security - CyberSentry UR (FW v7.4xx)

CyberSentry enables UR devices to deliver full cyber security features that help customers to comply with NERC CIP and NITIR 7628 cyber security requirements through supporting the following core features:

Password Complexity

Supporting up to 20 alpha- numeric or special characters, UR passwords exceed NERC CIP requirements for password complexity. Individual passwords per role are available.

AAA Server Support (Radius)

Enables integration with centrally managed authentication and accounting of all user activities and uses modern industry best practices and standards that meet and exceed NERC CIP requirements for authentication and password management.

Role Based Access Control (RBAC)

Efficiently administrate users and roles within UR devices. The new and advanced access functions allow users to configure up to five roles for up to eight configurable users with independent passwords. The standard “Remote Authentication Dial In User Service” (Radius) is used for authentication.

Event Recorder (Syslog for SEM)

Capture all cyber security related events within a SOE element (login, logout, invalid password attempts, remote/local access, user in session, settings change, FW update, etc), and then serve and classify data by security level using standard Syslog data format. This enables UR devices integration with established SEM (Security Event Management) systems.

EnerVista Software

The EnerVista™ suite is an industry-leading set of software programs that simplifies every aspect of using the G60 relay. The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the relay, and integrate information measured by the G60 into DCS or SCADA monitoring systems. Convenient COMTRADE and Sequence of Events viewers are an integral part of the UR setup software included with every UR relay, to carry out postmortem event analysis and ensure proper protection system operation.

UR-FW7.6-front-400px.jpg
UR Switch Module.jpg

UR Switch Module

T60 Brochure